Skip to content
October 18, 2026
TVG Report

TVG Report

Engineering-first robotics, AI, maker hardware, STEM, and creator technology reporting

  • Home
  • Tech News
  • Maker Culture
  • Robotics & AI
  • STEM Lab
  • NXT Bench
Main Menu

Tag: STEM Lab

Passive oscilloscope probe with cable and ground lead
STEM Lab

Oscilloscope Probe Loading: Fix the Measurement Before the Circuit

September 11, 2026September 13, 2026 - by TVG Editorial Team - Leave a Comment

A 10× probe can add capacitance and loop inductance that distort fast edges. Qualify compensation, grounding and bandwidth before diagnosing the board.

Oscilloscope Probe Loading: Fix the Measurement Before the Circuit Read More
Field Soldering Repair: A Four-Gate Go/No-Go Procedure
Maker Culture

Field Soldering Repair: A Four-Gate Go/No-Go Procedure

August 29, 2026August 31, 2026 - by TVG Editorial Team - Leave a Comment

Decide when a field solder repair can proceed, then control flux fume, hot-tool and power hazards and record the test that returns equipment to service.

Field Soldering Repair: A Four-Gate Go/No-Go Procedure Read More
Mechanical Switches or Capacitive Touch? Choose Inputs by Feedback and Conditions
STEM Lab

Mechanical Switches or Capacitive Touch? Choose Inputs by Feedback and Conditions

August 24, 2026September 1, 2026 - by TVG Editorial Team - Leave a Comment

For an accessible STEM build, choose mechanical or capacitive input by feedback, mounting, moisture and calibration—not by novelty.

Mechanical Switches or Capacitive Touch? Choose Inputs by Feedback and Conditions Read More
LED Strip Power Injection: Fix Voltage Drop Without Hiding the Risk
Maker Culture

LED Strip Power Injection: Fix Voltage Drop Without Hiding the Risk

August 23, 2026September 1, 2026 - by TVG Editorial Team - Leave a Comment

LED strip power injection can reduce voltage drop, but only when supply capacity, wire size, polarity, fusing and common-ground paths are designed together.

LED Strip Power Injection: Fix Voltage Drop Without Hiding the Risk Read More
Accessible maker lab tool wall with NFC and QR labels on bins and equipment
STEM Lab

NFC and QR Labels Can Make Maker Labs More Accessible if the Information Is Designed Well

August 7, 2026August 7, 2026 - by TVG Editorial Team - Leave a Comment

TVG Report explains nfc and qr labels can make maker labs more accessible if the information is designed well with practical engineering context, risks,.

NFC and QR Labels Can Make Maker Labs More Accessible if the Information Is Designed Well Read More
Organized maker lab with enclosed desktop 3D printer and routed ventilation duct
Maker Culture

3D Printer Enclosures Need a Ventilation Plan, Not Just Acrylic Walls

August 7, 2026August 7, 2026 - by TVG Editorial Team - Leave a Comment

TVG Report explains 3d printer enclosures need a ventilation plan, not just acrylic walls with practical engineering context, risks, source links, and what.

3D Printer Enclosures Need a Ventilation Plan, Not Just Acrylic Walls Read More
Realistic robot-vision test bench with small mobile robot, two unbranded camera modules, calibration checkerboard, AprilTag-style marker board, LED work li
Robotics & AI

Global Shutter vs. Rolling Shutter Is a Robot Vision Reliability Choice

August 5, 2026 - by TVG Editorial Team - Leave a Comment

Global shutter and rolling shutter cameras can both work in robot projects, but motion, lighting, calibration and cost decide which one belongs on the robot.

Global Shutter vs. Rolling Shutter Is a Robot Vision Reliability Choice Read More
Realistic home-lab networking bench with unbranded router, small sensors, mini server, Ethernet patch leads, RF interference test notes turned face down, w
STEM Lab

Wi-Fi 8 Should Be Judged by Reliability, Not Just the Next Router Badge

August 5, 2026 - by TVG Editorial Team - Leave a Comment

Wi-Fi 8 is expected to focus more on reliability than headline speed. For home labs, sensor networks and maker classrooms, the upgrade question should be latency, roaming, congestion and test discipline.

Wi-Fi 8 Should Be Judged by Reliability, Not Just the Next Router Badge Read More
Classroom robot camera aimed at matte fiducial markers with measuring tape and lights
Robotics & AI

AprilTag Print Size and Glare Can Break a Robot Demo Before the Code Does

August 4, 2026 - by TVG Editorial Team - 1 Comment

Before rewriting AprilTag code, check print size, border quality, glare, distance, camera calibration, and lighting. Many robot demo failures start on paper.

AprilTag Print Size and Glare Can Break a Robot Demo Before the Code Does Read More
Maker lab proximity test with Bluetooth beacons, robot chassis, and measured table
STEM Lab

Bluetooth Channel Sounding Gives Maker Labs a Better Proximity Test to Study

August 4, 2026 - by TVG Editorial Team - Leave a Comment

Bluetooth Channel Sounding can make proximity projects more rigorous, but only if students treat ranging as a measurement problem with calibration, logs, and failure cases.

Bluetooth Channel Sounding Gives Maker Labs a Better Proximity Test to Study Read More

Posts pagination

1 2 3 Next

Latest on X

@TVGReport
TVG Report review-policy graphic explaining supplied products, independent conclusions, and verified results

Wonder whether a supplied review unit changes the verdict? You're right to ask. TVG Report discloses supplied products, keeps conclusions independent, and separates manufacturer claims from verified results. Our review policy: #ProductReviews

Sep 18, 2026 · 10:03 AM PT

View on XRead the review policy
TVG Report infographic over a 3D-printing workbench highlighting first-layer, profile, and fit checks before adjusting and reprinting

You can lose an evening to a drifting first layer, a bad profile, or a part that prints cleanly and still does not fit. TVG Report looks past headline speeds to the checks, tradeoffs, and repair paths makers actually need. #3DPrinting

Sep 17, 2026 · 10:18 AM PT

View on XExplore Maker Culture
DS18B20 debugging infographic showing the 85.0°C power-on value, a three-wire probe, and checks for conversion, CRC, and power

A DS18B20 at exactly 85°C may be power-on data—not heat. Trust it after conversion completes and CRC passes. Our guide maps power mode and w1_therm checks.

Sep 16, 2026 · 3:54 PM PT

View on XRead the DS18B20 guide
Follow TVG Report on X

Latest Posts

Set DRV8871 Current Limit Without Confusing Peak and Continuous Current

Set DRV8871 Current Limit Without Confusing Peak and Continuous Current

October 17, 2026October 17, 2026

Calibrate PCF8523 RTC Drift and Check Backup Failures First

Calibrate PCF8523 RTC Drift and Check Backup Failures First

October 17, 2026October 17, 2026

GitHub License Compliance Goes GA as a Merge-Time Ruleset

GitHub License Compliance Goes GA as a Merge-Time Ruleset

October 17, 2026October 17, 2026

Adafruit LSM6DSOX six-degree-of-freedom inertial sensor breakout

LSM6DSOX FIFO Overruns: Set the Watermark From Your Drain Time

October 16, 2026October 16, 2026

Adafruit MAX31865 RTD PT100 or PT1000 amplifier breakout

MAX31865 RTD Readings Wrong? Check Reference Resistance and Lead Wiring

October 16, 2026October 16, 2026

GitHub code scanning alert with the Assign to Copilot control

GitHub Agentic Autofix Goes GA, but Validation Still Has Boundaries

October 16, 2026October 16, 2026

INA260 Alert Arrives Late? Calculate the Averaging Delay

INA260 Alert Arrives Late? Calculate the Averaging Delay

October 15, 2026October 15, 2026

MCP9808 Alert Pin Chatter? Match Hysteresis to Conversion Time

MCP9808 Alert Pin Chatter? Match Hysteresis to Conversion Time

October 15, 2026October 15, 2026

GitHub Actions Workflow Lockfiles Pin Direct and Transitive Dependencies

GitHub Actions Workflow Lockfiles Pin Direct and Transitive Dependencies

October 15, 2026October 15, 2026

TCS34725 Color Readings Drift? Control Gain, Exposure and Illumination

TCS34725 Color Readings Drift? Control Gain, Exposure and Illumination

October 14, 2026October 14, 2026

Seeed Studio reCamera Pro Review Preview: The Integration Is the Test

Seeed Studio reCamera Pro Review Preview: The Integration Is the Test

October 14, 2026October 14, 2026

DRV2605L Motor Silent? Separate Trigger, Actuator and Calibration Faults

DRV2605L Motor Silent? Separate Trigger, Actuator and Calibration Faults

October 14, 2026October 14, 2026

TVG Report

  • About TVG
  • Press Room / Media Kit
  • Event Coverage
  • Follow @TVGReport on X

Editorial Standards

  • Review Policy
  • Corrections Policy
  • Ethics & Editorial Disclosure

Business & Legal

  • Advertise & Sponsor
  • Privacy Policy
  • Terms of Service
Copyright © 2026 TVG Report.
Powered by WordPress and HitMag.